Enhanced Fujita scale damage indicators and degrees of damage, chapter 6


Motels (M)

Typical Construction:

Notes:

Table 6. Degree of Damage (DOD) for Expected (EXP), Lower Bound (LB) and Upper Bound (UB)
DOD Damage Description EXP LB UB
1 Threshold of visible damage 105 85 135
2 Loss of roof covering (up to 20%) 130 110 160
3 Broken windows or patio doors 145 120 170
4 Uplift of roof decking; significant loss of roof covering (more than 20%); loss of EIFS wall cladding 155 130 185
5 Uplift or collapse of canopy over driveway 160 130 190
6 Uplift or collapse of roof structure leaving most walls standing 200 165 230
7 Collapse of top story exterior walls 220 195 250
8 Collapse of most top story walls 230 205 260
9 Collapse of top two floors of three or more stories 275 230 300
10 Total destruction of entire building 305 260 350

*All wind speeds in km/h